Simulation Control Parameters
IORB
Flag for orbit correction. For any non-zero value the offset due to the wiggle motion is taken into account for the interaction between electron beam and radiation field. The correction is not included in the output values for the beam centroid position.
ISRAVG
If set to a non-zero value the energy loss due to spontaneous synchrotron radiation is included in the calculation.
ISRSIG
If set to a non-zero value the increase of the energy spread due to the quantum fluctuation of the spontaneous synchrotron radiation is included in the calculation.
VERSION
Used for backward compatibility of the input decks. Some parameters might change their behavior for older versions of GENESIS 1.3. The current version is 1.0. |